Keyboard shortcut: BP
Toolbar button:
![]()
Compatible with AutoCAD Versions:
13, 14, 2000, 2000i, 2002, 2004, 2005, 2006, 2007, 2008
Command to center bipass doors in a wall. The command determines the length of the walls and attempts to anticipate the desired size of the largest door that will fit in the selected wall. The size may be changed if needed and made as large or small as needed (within the limits of the wall length). The command will then break the walls and insert the doors.
User configurable options:
See Door Commands in the Floor Plan Cmds section of the APS Configuration Utility.
Layers:
The layer types for this command can be changed in the Assigning Layer Types to Commands portion of the Layer Control section of the APS-CONFIG command.
Known limitations:
Alternate uses:
None reported. If you have an alternate use for this command submit it here.
Command:
Command: BP
Command: BIPASS
Select base point on which to center bipass door or <Enter>/<Space> for MID2PT:
If the center of the wall can be found by using the midpoint of one of the wall lines, select the midpoint of that wall line now. The midpoint snap is added to your running object snaps if it is not already being used. If the base point location cannot be found using one of the standard object snaps press <Enter> or <Space> and use the MID2PT option which can locate the base point midway between any two points selected.
![]()
Select a point outside the wall lines to place the bipass door in:
Select the point.
![]()
Select a second point crossing all of the lines that make up the wall:
Select the second point of the crossing line that crosses the lines/plines/mlines that make up the wall. The following dialog will appear:
The maximum door size is displayed at the top of the dialog (the max width shown above is 6'-5"). This distance reflects any minimum framing widths that have been set up. (See Door Commands in the Floor Plan Cmds section of the APS Configuration Utility) If the door size that you need to enter is larger than the "Maximum door size" shown at the top it is possible to override the minimum framing requirements and insert a door size that is equal to the full length of the wall.
Select a size button or type in the values desired. Note: the buttons show feet and inch values ie: 4/0 means 4'-0" not 40".
-- The walls will be broken now and any jambs, sill lines, header lines, and/or demo lines will be drawn --
-- The doors will be drawn --
C-BIFOLD Command to center a bifold door/doors in a wall
C-CWIND Command to center commercial style windows in a wall
C-DDOOR Command to center double doors in a wall
C-OHEAD Command to center an overhead door in a wall
C-PATDOOR Command to center a patio door in a wall
C-RWIND Command to center a residential style window in a wall
C-SDOOR Command to center a single door in a wall
C-SLIDER Command to center a sliding glass door in a wall
|